— Knowledge —
— PRODUCTS —
Email:susie@hnljpump.com
Mobile:+8618507312158
TEL:+8613974960765
Vertical Sump Pump
发布时间:2024/3/6 0:17:55 人气: [content:visits]
Start pump and stop pump of vertical sump suspended pumps
Check the bearing cavity and let it keep a ration clean butter. Usually it's appropriate to fill with the empty cavity capac.
ityl/2-1/3, avoid the bearing temperature rising while running.
check whether the coupling is even on weight, otherwise you should find out the reason and get rid of it and then run itif adopting the exterior washing lubricating bearing bush, before starting the motor, lead the exterior liquid to wash thebearing bush.
Check the motor running direction and let it same as the ruled rotary direction of pump.
Close the gate valve and pressure meter on the outlet pipeline.
First start the motor and then open the pressure meter, slowly open the gate valve on the outlet pipeline to the desiredposition and then put into the normal running.
Normally stop, first close the outlet gate valve slowly and then stop the motor and close the pressure meter.Stop or no use for long fime, please remove the pump from the container, clean, reassemble and add oi to be stored.
China vertical sump pump manufacturer provides various stainless steel and duplex steel vertical sump pumps with affordable prices and stable performance. For more information, please contact 008613974960765.